Here are the key features of the eLogger V3:
Logs pack current to +/- 100 amps (150 amps optional) and voltage from about 4.5 volts to 70 volts.
Each unit is calibrated on a custom built calibration machine for the best accuracy.
The eLogger V3 has 4x the memory capacity of the V2 (128KB).
Current is measured with a true Hall Effects Sensor - NOT a resistance shunt which produces heat and sucks power from your system!
Great for bench monitoring of battery charging also!
Accepts optional inexpensive sensors for GPS, Temperature, RPM (brushless, magnetic or optical), Airspeed, Altitude, Servo Current, and more, available below
Logs Throttle Movement with optional Y-Cable
All data is logged to permanent memory, which retains the data even when the power is removed.
Software computes Wattage, mAH, etc. for complete e-flight data.
Fully Compatible with Windows 7 (32 and 64 bit), Vista, 98SE, ME, Win2K and XP™
Integrated USB with included cable (NOT a USB to serial port cable like other loggers)
Weighs about 0.7 oz (20 grams). Version with Wire Leads weighs slightly more.
Supports USB Live Mode, which lets you see what's happening in the model LIVE on the bench, on your PC
Adjustable logging rate (1-10 samples/second) and lossless data compression for long log times
Comes with our state of the art Windows virtual playback display and graphing
Powerful Graphing software has advanced charting features, such as amps vs volts
Internet Updatable firmware - as we add new features or (heaven forbid) have a firmware bug, the update is just a download away! No need to ship hardware back and forth.
Full support for English and Metric units